Colorado 1400

The HP/Colorado 1400 is a QIC-3010-class floppy-tape drive. Tapewyrm can select it and read its reports, but the bench unit has not referenced any tape, so no tape has been dumped on it.

Hardware likely bad

The only tested Colorado 1400 might well be bad, as it won't cleanly reference any tape that is presented to it. YMMV, I don't have another one to test with.

Identification

Values as reported by a bench unit:

Report Raw value Decoded
Vendor ID (32) 0x11C3 Make 71 (Colorado Memory Systems), model 3
ROM version (9) 0x79 ROM 121
Drive configuration (8) 0x98 QIC-80 mode bit set, 1 Mbit/s
Tape status (33) Supported Format UNKNOWN with every tape tried

Profile

Use --profile colorado.1400. It is a copy of colorado with the same wake sequence and timings:

Setting Value
Wake Phantom Select (46) + argument 0, then Enter Primary Mode (30)
Step pulse width 200 µs
Step gap 2000 µs (2.2 ms period)
Terminate gap 3000 µs
Report settle 900 µs

--profile auto does not try colorado.1400: its wake is identical to colorado, which auto already tries.

Formats and rates

Format Rate Status
QIC-3010 1 Mbit/s reported; 500 kbit/s is the standard rate Drive accepts the format and rate selects. No tape referenced.
QIC-80 500 kbit/s Refused: Select Rate or Format returns error 31.

Quirks

  • It does not reference tapes. Seek Load Point runs for about 29 s and ends Ready at BOT with no error, but the Referenced bit stays clear and Report Tape Status says format UNKNOWN. This happened with a QIC-80 tape and with a sealed factory QIC-3010 tape. The cause is not known; suspect the drive. Dump QIC-80 tapes on a Colorado Jumbo 350.
  • It refuses QIC-80 selects. Select Rate or Format (27) accepts format qic3010 and rate 1000, and rejects format qic80 and rate 500 with error 31 (Rate or Format Selection Error).
  • Cue Index pulses are about 2.0 ms apart, faster than the Jumbo 350's 2.9 ms. Both are inside Rev J's TINX range.
  • Read Data is gated during physical motion. Physical Forward (12) produces no Read Data transitions at all, on this drive and on the Jumbo
  • A physical-motion flux probe cannot tell you whether the read channel works; only a Logical Forward capture on a referenced tape can.
  • The cleaning cartridge on the bench is not detected. With it loaded the drive reports status 0x01 (Ready, no cartridge present) and Physical Forward fails with error 2 (Cartridge Not Present or Removed). A data tape in the same drive is detected, so the switch works and the cartridge shell does not reach it. tw drive clean cannot run with that cartridge, and no software option can force it: the drive refuses to move. See Cartridges.

See also