TEAC FT-3010

The TEAC FT-3010 is a QIC-3010-capable floppy-tape drive that also reports QIC-80 mode. It needs a tighter command cadence than the Colorado drives, and it fails hard when a report is left unfinished.

Identification

Values as reported by a bench unit (label on the unit: TEAC):

Report Raw value Decoded
Vendor ID (32) 0x01CC Make 7 (Wangtek/Rexon/Tecmar), model 12. ftape names this word "Wangtek 3200 / Teac 700".
ROM version (9) 0x8C ROM 12, beta bit set
Drive configuration (8), no cartridge 0x90 QIC-80 mode, 500 kbit/s
Drive configuration (8), QIC-3010 cartridge 0x50 Extra-length tape, 500 kbit/s
Drive status (6), no cartridge, idle 0x09 Ready, write protected
Tape status (33), preformatted QIC-3010 400 ft 0x64 QIC-3010, variable length 900 Oe

The vendor word is shared: TEAC shipped this generation under the ID ftape lists for the Wangtek 3200. The ftape entry named "Teac FT3010TR" is a different word, 0x03CF (make 15). Trust the label on the unit.

tw currently labels configuration 0x50 as "QIC-40 mode", because bit 7 (the QIC-80 mode flag) is clear. On a QIC-3010 drive with a QIC-3010 cartridge inserted, that bit carries no meaning; read the rate bits only.

Profile

Use --profile teac. It inherits generic and uses the colorado wake (Phantom Select + Enter Primary Mode), with tighter timings:

Setting Value Why
Wake Phantom Select (46) + argument 0, then Enter Primary Mode (30) What the drive answers.
Step pulse width 200 µs Inherited from generic.
Step gap 1300 µs (1.5 ms period) Centre of Rev J TSTEP (0.9–2.1 ms). The Colorado profiles' 2.2 ms period splits pulse trains on this drive.
Terminate gap 3300 µs (3.5 ms from the last leading edge) Past the 2.9 ms command time-out maximum.
ACK window 10 ms Inherited from generic.
Vendor IDs 0x01CC Lets tw suggest this profile when it sees the word.

With this profile the bench unit passed 600 of 600 reports in 60 s and two clean load points.

Formats and rates

Format Rate Status
QIC-3010 500 kbit/s References a preformatted 400 ft QIC-3010 tape.
QIC-80 500 kbit/s Reports QIC-80 mode. A blank QIC-80 cartridge does not reference, as expected.

Quirks

  • The command time-out is about 2.2 ms. The drive acknowledges a report 2.2 ms after the last Step pulse, the bottom of Rev J's TTIMEOUT range (2.2–2.9 ms). At a 2.2 ms Step period a pulse train can split: the drive sees a stray single pulse (Soft Reset) or a stray five (Alternate Command Time-out). Use the teac profile's 1.5 ms period.
  • Alternate Command Time-out moves the ACK to about 6.25 ms. If a split train sends command 5, the drive's time-out becomes Rev J's alternate 6.2–6.9 ms, and reports acknowledge too late for a short ACK window. Only a Soft Reset or a power cycle clears that state. The generic 10 ms ACK window tolerates it.
  • Never leave a report half-clocked. An ACK timeout, tw drive scope --pulses N with a report command, or a Soft Reset in the middle of a report leaves the drive in the report subcontext. Later commands are "illegal in report subcontext", and then every output goes dark: no cue Index, no Track Zero, no Write Protect, no response to any select. Only a power cycle brings it back.
  • Automatic Seek Load Point waits for the first status report. After a cartridge is inserted, the drive holds its automatic load point until the first Report Drive Status (Rev J permits this, command 14). It then runs for about 30–50 s, during which it is not Ready and often does not acknowledge reports at all. Report Error Code (7) is rejected until it is Ready (Rev J Table 2a), so tw drive status shows it as not supported. wake() waits this out.
  • New-cartridge latch. The first load point after insertion can end Ready with the new-cartridge and error bits still set, and a Seek Load Point sent while the latch is set is rejected. Read the error code, then run the load point again.
  • Cue Index free-runs. Index pulses arrive every 2.5 ms, 0.9 ms wide, in every state, including during pulse trains and reports. Index-edge report timing and the firmware's wait-ready mean nothing on this drive; the profile uses fixed settle times.
  • Unexplained software-reset error. After 11 idle minutes with nothing sent, the bench unit came up with error 27 (Software Reset Occurred) latched and ran its automatic load point on the first status. The cause is not known. wake() absorbs it.